Engineering.

Design and coordinate the power, cooling and building systems your data center needs. Our work includes MEPF design, CFD airflow analysis, controls and BIM coordination.

Multidisciplinary MEPRoles DefinedStandards-led Scope
Discuss Your Project→
Rows of server racks in a data center
Resilience ObjectivesCredentials on RequestSustainability InputsHigh-Density PlanningCFD AnalysisBMS Integration
Core Capabilities

Data center design and coordination scopes

We start with your capacity, resilience targets and project stage. Then we agree the calculations, models and drawings to deliver, along with review and certification responsibilities.

01

Electrical Engineering

Power distribution, backup systems and electrical calculations for the facility's operating loads.

Complete MEPF design and cable sizing
Panel backup and DG design
UPS and generator power integration
Load bank testing protocols
Electrical load calculations
MV/LV power distribution
02

Mechanical Systems

Cooling design and airflow analysis for the heat your equipment produces, including containment and fire protection.

Cooling load calculations and optimization
CFD analysis for airflow management
Fire suppression system design
Plumbing and drainage design
Hot/cold aisle containment design
Chiller & CRAC system design
03

Security & Monitoring

Access control, CCTV and building monitoring systems coordinated with the facility design.

Access control systems design
CCTV integration and review
ELV design review
Lighting design for security and efficiency
BMS integration
Monitoring systems design
04

Technical Drawing Review

Review drawings against the design requirements and track the changes needed before issue.

MEPF drawing comprehensive review
CCTV and access control documentation
Stage-wise installation inspection
Pre-commissioning document review
Shop drawings review
As-built documentation
05

Commissioning & Certification Support

Prepare and review commissioning documents. We agree certification requirements and the responsible assessor with your team.

Testing and commissioning review
Review of commissioning activities
Final commissioning validation
Certification documentation support
Handover documentation
Post-completion support
Project requirements

Standards for Your Project

We agree the relevant codes and client requirements for each project. Final design and certification approvals remain with the appointed parties.

ASHRAE
SMACNA
IPC
NFPA
BS
ASTM
BIS
LEED
Why Partner With Us

Your Extended
Engineering Team.

Add the engineering support your project needs. We agree the team, drawings and review dates with you before work starts.

Get Started→

MEP Experience

Electrical, mechanical and plumbing support at the design stage your project has reached.

The Right Disciplines

We agree the experience, software skills and credentials your project needs before assigning the team.

HPC & Hyperscale Requirements

Plan power and cooling around the rack loads, redundancy and control requirements.

Your Project Standards

We identify the applicable ASHRAE, SMACNA, NFPA and local requirements with your team.

A Clear Delivery Plan

Agree what you will receive, when you will review it and how each package will be checked.

Time to Work Together

Set meeting times and response windows that work for your team and ours in Bangalore.

Expertise

Types of Projects We Can Support

Hyperscale Data Centers

Large-scale facilities with complex MEPF requirements

Colocation Facilities

Multi-tenant data centers with modular design needs

HPC PODs

High-density computing power, cooling, controls, and coordination requirements

DC Upgrades

Expansion and modernization of existing facilities

Working with Spetia

Plan your next
data center.

Tell us about the facility you are planning or upgrading. We can help with the design, calculations and coordination.

Talk About Your Project

Start with the load

Rack layouts, IT loads and operating conditions shape the work. We use them to agree the power and cooling requirements with your team.

See what the design shows

Review the layouts, calculations and any airflow studies together. Assumptions and open questions stay with the work, so the next design decision has a clear basis.

Read the project guide

CFD tests defined operating conditions. Commissioning, certification and final design approvals are separate responsibilities.

Technical details to agree before we start

Starting information

  • The site, design stage, resilience requirements and review team
  • IT loads, rack layouts, cooling system and operating conditions
  • Current models, drawings, equipment data and project standards

Deliverables

  • The agreed building-services models, layouts and drawings
  • Calculations or airflow simulation reports included in the scope
  • A record of assumptions, open questions and items to coordinate

Review checks

  • Loads and assumptions against the agreed design requirements
  • The normal and failure scenarios included in the analysis
  • Coordination issues and the response to each review comment

Computational fluid dynamics (CFD) results apply to the conditions tested. Record the loads, boundary conditions, mesh checks and pass criteria. Simulation does not replace commissioning or certify a facility. Agree certification, permits and final approval roles separately.